automatic bilge pump will not shut off

Post by Johnny »

The automatic bilge pump on my 2008 Cobalt 232 will not shut off. I replaced the pump when the problem first occurred. Unfortunately, the same thing happened again with the new bilge pump. There is no water in the bilge which would engage the float switch. I have inspected the wiring and can find nothing wrong. Also, the radio will not work when the automatic bilge pump goes on and on. In order to shut the pump off, I disconnected the wiring. Has anyone experienced issue like this?
User avatar
AsLan7
Fleet Admiral
Fleet Admiral
Posts: 11501
Joined: Sat Jul 29, 2017 10:58 am
Location: Erie PA
Has thanked: 1 time
Been thanked: 5 times
Contact:

Re: automatic bilge pump will not shut off

Post by AsLan7 »

.
Hey Johnny...welcome to the Cobaltchat forum. So glad you found us!

If it does not turn off then normally the culprit is a stuck micro-switch on the float mechanism or the helm switch is engaged overriding the float. Since you already checked this and replaced the pump with now similar results it sounds like you may have a bad ground somewhere in the switch which is possibly grounding (or completing the switch circuit) through the radio. Do you have an electrical tester?

Btw any pics?

Again welcome aboard mate!



.
You do not have the required permissions to view the files attached to this post.
2002 Cobalt 262
&
2005 Cobalt 263
496 MagHO
(sold )
Erie, PA
Currently boatless (for now)
will fly for food

(CChat moderator)
Johnny
Ensign
Ensign
Posts: 4
Joined: Mon Apr 26, 2021 12:07 pm
Location: South Carolina
Contact:

Re: automatic bilge pump will not shut off

Post by Johnny »

Thanks for your reply and help. I will check the grounding. Yes, I have a tester and will use it to hopefully find the problem. Thanks!
SAB220
Captain
Captain
Posts: 322
Joined: Fri Sep 23, 2016 7:44 am
Location: Maine
Contact:

Re: automatic bilge pump will not shut off

Post by SAB220 »

Johnny I would bench test the pump to confirm it works. No way should be a any connection to the radio. The bilge pump circuit is separate from every other circuit for obvious reasons. Matter of fact the radio may be the symptom of the problem.

Need to solve this problem before you go out. If it bench test O'K its got to be a helm switch/radio. Worst come to worst wire it directly to the starting battery because the float acts as the switch unless it on the trailer. These no silver bullet to solving this. There plenty on line on this very subject
2004 220
User avatar
bruceb58
Vice Admiral
Vice Admiral
Posts: 1257
Joined: Tue Nov 24, 2020 11:10 pm
Location: Lake Tahoe
Contact:

Re: automatic bilge pump will not shut off

Post by bruceb58 »

I agree there may be a sneak path happening here. To confirm, disconnect the wires to the bilge switch at the dash to see if that keeps the pump off.
2017 R5 350HP Mercruiser Bravo III
Northridge, CA
Big Bear Lake, CA
South Lake Tahoe, CA
Johnny
Ensign
Ensign
Posts: 4
Joined: Mon Apr 26, 2021 12:07 pm
Location: South Carolina
Contact:

Re: automatic bilge pump will not shut off

Post by Johnny »

Thanks guys! I appreciate your assistance. I will let you know what I find.
User avatar
Mike in SC
Captain
Captain
Posts: 327
Joined: Sun Jul 14, 2019 9:37 pm
Location: Lake Murray, SC
Contact:

Re: automatic bilge pump will not shut off

Post by Mike in SC »

Is it still running?
Mike in SC
Lake Murray, SC
2003 Cobalt 220
350 Mag MPI/Merc Bravo 3
Johnny
Ensign
Ensign
Posts: 4
Joined: Mon Apr 26, 2021 12:07 pm
Location: South Carolina
Contact:

Re: automatic bilge pump will not shut off

Post by Johnny »

Hi Mike, I have the auto bilge off, but there remains a problem with the electrical system. Battery 1 discharges very quickly, radio will not work, etc. We have had two thunderstorms with major rain over the last few days, and I went down afterwards to turn on the manual pump. I have tried everything that I know to do, and decided to bite the bullet and take it in for service. Thanks so much for your response.
Stagdad
Commander
Commander
Posts: 198
Joined: Fri Nov 02, 2018 1:51 am
Location: The Bluegrass State
Contact:

Re: automatic bilge pump will not shut off

Post by Stagdad »

It happened to me while out one day, whacked the top to the pump with a stick and un stuck the float. has not acted up since.
Stagdad(Brian & Linda)
220s V8 300VP
Home Port Northern KY
Away Port Lake Cumberland / Dale Hollow
User avatar
Mike in SC
Captain
Captain
Posts: 327
Joined: Sun Jul 14, 2019 9:37 pm
Location: Lake Murray, SC
Contact:

Re: automatic bilge pump will not shut off

Post by Mike in SC »

Johnny wrote: Thu May 06, 2021 6:18 am Hi Mike, I have the auto bilge off, but there remains a problem with the electrical system. Battery 1 discharges very quickly, radio will not work, etc. We have had two thunderstorms with major rain over the last few days, and I went down afterwards to turn on the manual pump. I have tried everything that I know to do, and decided to bite the bullet and take it in for service. Thanks so much for your response.
Was just hoping you'd found a resolution.
Hope it's cheap!
Mike in SC
Lake Murray, SC
2003 Cobalt 220
350 Mag MPI/Merc Bravo 3