I recently purchased a 1999 Cobalt 293 and the bilge area under the step has some missing pieces.

1. There is a shower sump with float wired to a 2 pin connector - it currently is not receiving 12 VDC power can someone confirm it's activated through the water system breaker? If not, welcome feedback since I am unable to get it to have 12VDC.

2. There is a fwd bilge activated through a 4 pin connector with two wires manually activating the bilge through the switch at the helm. This works.

3. There is a red wire to the 4 pin connector that is removed, and two wires output from the connector that are also cut and open. I assume this was to a float switch in the bilge that was tied to always hot and would activate the fwd bilge without the switch.

Appreciate confirmation on these items and then a part number of what float switch was used if #3 is accurate so I can replace. I have contacted the Cobalt dealer who reached out to Cobalt and said electrical diagrams are no longer available for the model.

Thanks!
User avatar
AsLan7
Fleet Admiral
Fleet Admiral
Posts: 11505
Joined: Sat Jul 29, 2017 10:58 am
Location: Erie PA
Has thanked: 1 time
Been thanked: 5 times
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by AsLan7 »

.
Hey K34. Welcome to the Cobaltchat forum. So glad you found us!

Can’t help you with the shower sump pump but our bilge pump has a red hot wire to the battery which allows power to activate if the float rises.

Are there any pics of your 293? We enjoy them here.

Again welcome aboard mate!

.
You do not have the required permissions to view the files attached to this post.
2002 Cobalt 262
&
2005 Cobalt 263
496 MagHO
(sold )
Erie, PA
Currently boatless (for now)
will fly for food

(CChat moderator)
kmulde34
Ensign
Ensign
Posts: 4
Joined: Sat Oct 31, 2020 3:41 pm
Location: Michigan
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by kmulde34 »

Thanks! Here are some pictures.
You do not have the required permissions to view the files attached to this post.
User avatar
Big Block Power
Fleet Admiral
Fleet Admiral
Posts: 17930
Joined: Sat May 07, 2016 8:05 pm
Location: Neenah,Wi
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by Big Block Power »

I would think you could use any float switch that would fit in that area. They are universal parts anyways. Rule makes a bunch. I can only guess someone removed it to replace it and just never got back to it. Like A7 said red is constant hot.

https://www.westmarine.com/buy/rule-ind ... 4REALw_wcB
You do not have the required permissions to view the files attached to this post.
03Cobalt220 8.1gxi DP
"Kids in Tow2"
"Pot The Jus" Originator :-)
Neenah Wi
#ItsBu'sfault
#FARCON Marine CC Core!
Holy Smokes
Captain
Captain
Posts: 383
Joined: Mon May 07, 2018 2:16 pm
Location: KS
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by Holy Smokes »

Owned a 1999 293 for 7 years. I've attached the wiring diagrams and water line routing I got from Cobalt.

If not accessible here, drop me an email and I can send you all the documents I acquired over the years.
You do not have the required permissions to view the files attached to this post.
2005 Cobalt 360, 496Mag HO's with Bravo 3X drives

LOTO - Lake of the Ozarks
User avatar
Big Block Power
Fleet Admiral
Fleet Admiral
Posts: 17930
Joined: Sat May 07, 2016 8:05 pm
Location: Neenah,Wi
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by Big Block Power »

Wow well look at that. Give that guy a beer or 3👍
03Cobalt220 8.1gxi DP
"Kids in Tow2"
"Pot The Jus" Originator :-)
Neenah Wi
#ItsBu'sfault
#FARCON Marine CC Core!
User avatar
AsLan7
Fleet Admiral
Fleet Admiral
Posts: 11505
Joined: Sat Jul 29, 2017 10:58 am
Location: Erie PA
Has thanked: 1 time
Been thanked: 5 times
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by AsLan7 »

Holy Smokes wrote: Mon Nov 02, 2020 11:23 am Owned a 1999 293 for 7 years. I've attached the wiring diagrams and water line routing I got from Cobalt.

If not accessible here, drop me an email and I can send you all the documents I acquired over the years.
.
Nice HS!
2002 Cobalt 262
&
2005 Cobalt 263
496 MagHO
(sold )
Erie, PA
Currently boatless (for now)
will fly for food

(CChat moderator)
kmulde34
Ensign
Ensign
Posts: 4
Joined: Sat Oct 31, 2020 3:41 pm
Location: Michigan
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by kmulde34 »

I can't believe it. This group is great! Thanks so much for the outstanding support.
kmulde34
Ensign
Ensign
Posts: 4
Joined: Sat Oct 31, 2020 3:41 pm
Location: Michigan
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by kmulde34 »

Based on the great support there is a 4A AGC fuse behind the distribution panel from the Water System that powers the shower sump. This fuse was blown.

There is a 26012 Johnson Pump float switch that was removed and not replaced in the front bilge.

Everything is now all set - thanks everyone!
User avatar
AsLan7
Fleet Admiral
Fleet Admiral
Posts: 11505
Joined: Sat Jul 29, 2017 10:58 am
Location: Erie PA
Has thanked: 1 time
Been thanked: 5 times
Contact:

Re: Cobalt 293 Fwd Bilge / Sump Wiring Question

Post by AsLan7 »

kmulde34 wrote: Mon Nov 02, 2020 6:49 pm Based on the great support there is a 4A AGC fuse behind the distribution panel from the Water System that powers the shower sump. This fuse was blown.

There is a 26012 Johnson Pump float switch that was removed and not replaced in the front bilge.

Everything is now all set - thanks everyone!
.
Great to hear ...and thanks for the follow up kmulde34! 👍